Thermal Overcurrent Circuit Breakers 2-5000/2-5700 for aircraft

Single pole thermal circuit breaker with press-to-reset, tease-free,
trip-free, snap action mechanism. Type 2-5000 is available with optional
manual release (-H), type 2-5700 can be supplied as a push-push
switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset
configuration; M-type when fitted with manual release -H; S-type
with push-push operation). Fitted with flange or threadneck for panel mounting. Options include an additional unprotected circuit tap (-A3). Approved to CBE standard EN 60934 (IEC 60934).
For further details please see chapter: Technical Information
Voltage ratingAC 250 V; DC 28 V
(UL: AC 250 V; DC 50 V)
Current rating range0.05...25 A
Typical lifeAC 250 V / DC 28 V:
0.05...16 A 5,000 operations at 2 x IN, inductive
17...25 A5,000 operations at 2 x IN, resistive
Ambient temperature-20...+60 (-4...+140 )
Insulation co-ordinationrated impulsepollution
(IEC 60664 and 60664 A) withstand voltagedegree
2.5 kV2
reinforced insulation in operating area
Dielectric strength
(IEC 60664 and 60664A) test voltage
operating areaAC 3,000 V
Insulation resistance> 100 MΩ (DC 500 V)
Interrupting capacity Icn0.05...2.5 A8 x IN
3...5 A20 x IN
6...12 A200 A
(higher interrupting capacity
available to special order)
13...25 A300 A
Interrupting capacityINUN
(UL 1077)0.05...20 AAC 250 V2,000 A
0.05...25 ADC 50 V2,500 A
(higher values upon request)
Degree of protectionoperating area IP40
(IEC 60529/DIN 40050)terminal area IP00
Vibration8 g (57-500 Hz) ?0.61 mm (10-57 Hz),
to IEC 60068-2-6, test Fc,
10 frequency cycles/axis
Shock25 g (11 ms)
to IEC 60068-2-27, test Ea
Corrosion96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
Humidity240 hours at 95 % RH
to IEC 60068-2-78, test Cab
Massapprox. 29 g
2013/14
ww
w.e-t-a
- JTP mine winchDetailed Product Description:It mainly used for hoist shaft and inclined to upgrade coal, ore, waste...
- JH series mine winchIt is mainly suitable for back-cover under the mine or tow heavy article horizontally. Both winch el...
- JD series mine winchModel JD-1 (JD-11.4) JD-1.6 (JD-25) JD-2.5 (JD-40) JD-3 (JD-45) Traction KN 10 16 25 30 Rope speed m...
- JZ series mine winchJZ series sinking winches have advantages of strong ability of hoisting ,large capacity of rope,stab...